soccer club 1 soccer club 2 soccer club 3 soccer club 4 soccer club 5 soccer club 6 soccer club 7

Fire alarm

Conventional System:

Conventional systems are designed to give a basic zonal and alarm call to the occupiers of a building. Panels can be standard or high specification and only go up to 32 zone therefore if you need a bigger system an addressable would be more economical.

Addressable System:

Addressable systems are designed to be more specific on the location of the fire and can be programmed with location names for ease of use. Operates on a single 2 core loop cutting on installation costs in larger properties. Each loop is monitored every 4 seconds to ensure consistency throughout the building.

Products

Model

Hochiki HFP CP-4

Description

HFP 4 Zone Conventional Control Panel
Note: 1.Add 2 batteries , Each 12V / 2 AH

Made in UK


Model

Hochiki HFP CP-8

Description

HFP 8 Zone Conventional Control Panel
Note: 1.Add 4 batteries , Each 12V / 2 AH

Made in UK


Model

Hochiki SOC-E3

Description

Photoelectric Smoke Detector

Made in UK


Model

Hochiki DCD-AE3

Description

Combined 60 degrees Heat Detector

Made in UK


Model

Hochiki BANSHEE EXCEL

Description

Conventional Sounder (Banshee) Red c/w shallow base

Made in UK


Model

Hochiki HCP-E(SCI)

Description

Conventional Call Point with Back Box Red

Made in UK


Model

Hochiki HFP AP-1ASLS
(Syncro)

Description

Lp Panel c/w 16 zones, non-networkable, surface
Note: 1.Add 2 batteries , Each 12V / 7 AH

Made in UK


Model

Hochiki HFP AP-1ASS
(Syncro)

Description

Lp Panel c/w 16 zones, networkable, surface , Expandableto 2 loops
Note: 1.Add 2 batteries , Each 12V / 7 AH

Made in UK


Model

HFP AP-2ASS
(Syncro)

Description

Lp Panel c/w 16 zones, surface , Networkable
Note: 1.Add 2 batteries , Each 12V / 7 AH

Made in UK


Model

Hochiki ALN-EN

Description

Intelligent Photoelectric Smoke Sensor

Made in UK


Model

Hochiki ACC-EN

Description

Multi-Sensor – Photoelectric and Heat

Made in UK


Model

Hochiki ATJ-EN

Description

Analogue Heat Sensor

Made in UK


Model

Hochiki CHQ-WS2

Description

Wall Sounder Beacon , Red

Made in UK


Model

Hochiki HCP-E(SCI)

Description

Addressable Call Point with SCI Red

Made in UK


Model

HP101-4
HP101-8
HP101-16

Description

4/8/16 Zones Fire Alarm Control Panel
2port sounder, 2port fire relay output, 1port fault relay output, 1Port
resettable power 28V, 1port premium power 28V, Maximum number can be
connected 30 detector to area
UL (864) listed From Intertek

Made in UK


Model

HD101-B

Description

Conventional Smoke Detector

Made in UK


Model

HD102-B

Description

Conventional Heat Detector

Made in UK


Model

HD103-B

Description

Conventional MULTI Detector

Made in UK


Model

HC102

Description

Conventional Call Point Pull Down type

Made in UK


Model

HC101

Description

Conventional call point push type

Made in UK


Model

HP201-2

Description

Professional Addressable Panel 2Loop each Loop 247 Address can be
Programmed by Computer
Large Display , Switched mode Power supply
Programmable sounder and Relays

Made in UK


Model

HD201

Description

Optical Addressable Smoke Detector

Made in UK


Model

HD202

Description

Addressable Heat Detector

Made in UK


Model

HD203

Description

Addressable Multi Sensor(Smoke and Heat)

Made in UK


Model

HC202

Description

Addressable Call Point Pull Down type

Made in UK