Fire alarm
Conventional System:
Conventional systems are designed to give a basic zonal and alarm call to the occupiers of a building. Panels can be standard or high specification and only go up to 32 zone therefore if you need a bigger system an addressable would be more economical.
Addressable System:
Addressable systems are designed to be more specific on the location of the fire and can be programmed with location names for ease of use. Operates on a single 2 core loop cutting on installation costs in larger properties. Each loop is monitored every 4 seconds to ensure consistency throughout the building.
Products
Model
Hochiki HFP CP-4
Description
HFP 4 Zone Conventional Control Panel
Note: 1.Add 2 batteries , Each 12V / 2 AH
Made in UK
Model
Hochiki HFP CP-8
Description
HFP 8 Zone Conventional Control Panel
Note: 1.Add 4 batteries , Each 12V / 2 AH
Made in UK
Model
Hochiki SOC-E3
Description
Photoelectric Smoke Detector
Made in UK
Model
Hochiki DCD-AE3
Description
Combined 60 degrees Heat Detector
Made in UK
Model
Hochiki BANSHEE EXCEL
Description
Conventional Sounder (Banshee) Red c/w shallow base
Made in UK
Model
Hochiki HCP-E(SCI)
Description
Conventional Call Point with Back Box Red
Made in UK
Model
Hochiki HFP AP-1ASLS
(Syncro)
Description
Lp Panel c/w 16 zones, non-networkable, surface
Note: 1.Add 2 batteries , Each 12V / 7 AH
Made in UK
Model
Hochiki HFP AP-1ASS
(Syncro)
Description
Lp Panel c/w 16 zones, networkable, surface , Expandableto 2 loops
Note: 1.Add 2 batteries , Each 12V / 7 AH
Made in UK
Model
HFP AP-2ASS
(Syncro)
Description
Lp Panel c/w 16 zones, surface , Networkable
Note: 1.Add 2 batteries , Each 12V / 7 AH
Made in UK
Model
Hochiki ALN-EN
Description
Intelligent Photoelectric Smoke Sensor
Made in UK
Model
Hochiki ACC-EN
Description
Multi-Sensor – Photoelectric and Heat
Made in UK
Model
Hochiki ATJ-EN
Description
Analogue Heat Sensor
Made in UK
Model
Hochiki CHQ-WS2
Description
Wall Sounder Beacon , Red
Made in UK
Model
Hochiki HCP-E(SCI)
Description
Addressable Call Point with SCI Red
Made in UK
Model
HP101-4
HP101-8
HP101-16
Description
4/8/16 Zones Fire Alarm Control Panel
2port sounder, 2port fire relay output, 1port fault relay output, 1Port
resettable power 28V, 1port premium power 28V, Maximum number can be
connected 30 detector to area
UL (864) listed From Intertek
Made in UK
Model
HD101-B
Description
Conventional Smoke Detector
Made in UK
Model
HD102-B
Description
Conventional Heat Detector
Made in UK
Model
HD103-B
Description
Conventional MULTI Detector
Made in UK
Model
HC102
Description
Conventional Call Point Pull Down type
Made in UK
Model
HC101
Description
Conventional call point push type
Made in UK
Model
HP201-2
Description
Professional Addressable Panel 2Loop each Loop 247 Address can be
Programmed by Computer
Large Display , Switched mode Power supply
Programmable sounder and Relays
Made in UK
Model
HD201
Description
Optical Addressable Smoke Detector
Made in UK
Model
HD202
Description
Addressable Heat Detector
Made in UK
Model
HD203
Description
Addressable Multi Sensor(Smoke and Heat)
Made in UK
Model
HC202
Description
Addressable Call Point Pull Down type
Made in UK